Displaying Line Impedance Test Results

After you have run the line impedance test (as described in Running the Line Impedance Test), you can view the test results. The results include a list of impedance values and DC levels relative to the measured ERL values. The higher the ERL, the better the impedance.

To view line impedance test results:
1. Access the device's Command Shell.
2. On the command-line prompt, enter the following command:
/VoiceEngn/AnalogLineTest>AnalogLineTestResults

The following example displays test results of FXO channel 4, where the Impedance 0 (600 Ohms) returns the best (highest) ERL (25.66):

/VoiceEngn/AnalogLineTest>AnalogLineTestResults
The Analog Line Test Measurements for CID 4:
Analog Line Test successfully completed.

The AnalogLineTestResults command only displays the results of the last test that was run.